Dissolved Oxygen: 0~40mg/L, 0~400%;
Customizable measuring range, displayed in ppm unit.
1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.
2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.
3.Carefully select materials and strictly select each circuit component, which greatly improves the stability of the circuit during long-term operation.
4.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.
5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.
6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.
Electrical connections Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it. Instrument installation method Technical specifications| Measurement range | 0~40.00mg/L; 0~400.0% |
| Measurement unit | mg/L; % |
| Resolution | 0.01mg/L; 0.1% |
| Basic error | ±1%F.S |
| Temperature | -10~150℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Basic error | ±0.3℃ |
| Current Output | 4~20mA,20~4mA,(load resistance<750Ω) |
| Communication output | RS485 MODBUS RTU |
| Relay control contacts | 5A 240VAC,5A 28VDC or 120VAC |
| Power supply (optional) | 85~265VAC,9~36VDC,power consumption≤3W |
| Working conditions | No strong magnetic field interference around except the geomagnetic field. |
| Working temperature | -10~60℃ |
| Relative humidity | ≤90% |
| IP rate | IP65 |
| Instrument Weight | 0.8kg |
| Instrument Dimensions | 144×144×118mm |
| Mounting hole dimensions | 138*138mm |
| Installation methods | Panel,Wall mounted,pipeline |
|
Model No. |
CS4763 |
|
Measuring Mode |
Polarography |
|
Housing Material |
POM+Stainless steel |
|
Waterproof Rating |
IP68 |
|
Measuring Range |
0-20mg/L |
|
Accuracy |
±1%F.S |
|
Pressure Range |
≤0.3Mpa |
|
Temperature Compensation |
NTC10K |
|
Temperature Range |
0-50℃ |
|
Calibration |
Anaerobic Water Calibration and Air Calibration |
|
Connection Methods |
4 core cable |
|
Cable Length |
Standard 10m cable, can be extended |
|
Installation Thread |
NPT3/4’’ |
|
Application |
General application, river, lake,drink water, environment protection ,etc |
|
Model No. |
CS4773 |
|
Measuring Mode |
Polarography |
| HousingMaterial | POM+Stainless steel |
|
Waterproof Rating |
IP68 |
|
Measuring Range |
0-20mg/L |
|
Accuracy |
±1%F.S |
| PressureRange | ≤0.3Mpa |
| Temperature Compensation | NTC10K |
|
Temperature Range |
0-50℃ |
|
Calibration |
Anaerobic Water Calibration and Air Calibration |
|
Connection Methods |
4 core cable |
|
Cable Length |
Standard 10m cable, can be extended |
|
Installation Thread |
Upper NPT3/4’’,1’’ |
|
Application |